Skip navigation

therm-RP 1200 | EH

Ord. no. 638452

The Kränzle therm-RP series is particularly suitable for applications where an above-average flushing effect at high working pressure is required. Thanks to the innovative in-line pump, these hot water units offer a water output of up to 1600 l/h as well as other convincing features.

  • Quick release plug-in system D12
  • Kränzle in-line RP pump
  • Total-stop system with delayed motor cut-of
  • Safety shutdown
  • Pressure regulation
  • Twist-Stop screw connection
  • Cleaning Agent Intake
  • Locking brake
  • Direct suction: Suction height 2.5 m
  • Water tank: Volume 12 liters
  • Stainless steel heating coil
  • Digital thermostat
  • Flow monitor
  • Combustion chamber pre-ventilation
  • Visual flame monitoring
  • Overheating protection
  • Burner stops when there is a lack of heating oil
  • Operating hours meter
  • Fuel tank: 35 liters
  • Removable covers
  • Accessory storage
  • Digital control panel
  • Visual flame monitoring and Overheating protection
Operating pressure
70-190 bar
Water output
20 l/min
Connection Voltage
400 V
Connection Phase
3 ~
Connection Frequency
50 Hz
Hot water output
12-80 °C
Automotive industry, haulage companies
Agriculture, livestock farming
Public service, construction
Sanitary, food
Industry

Technical details

therm-RP 1200 | EH
Ord. no. 638452
therm-RP 1200 T | EH
Ord. no. 638462
therm-RP 1400 | EH
Ord. no. 638650
therm-RP 1400 T | EH
Ord. no. 638660
therm-RP 1600 | EH
Ord. no. 638850
therm-RP 1600 T | EH
Ord. no. 638860
Ord. no. 638452638462638650638660638850638860
Operating pressure bar therm-RP 1200 | EH 70-190 bar therm-RP 1200 T | EH 70-190 bar therm-RP 1400 | EH 70-170 bar therm-RP 1400 T | EH 70-170 bar therm-RP 1600 | EH 70-150 bar therm-RP 1600 T | EH 70-150 bar
Operating pressure MPa therm-RP 1200 | EH 7-19 MPa therm-RP 1200 T | EH 7-19 MPa therm-RP 1400 | EH 7-17 MPa therm-RP 1400 T | EH 7-17 MPa therm-RP 1600 | EH 7-15 MPa therm-RP 1600 T | EH 7-15 MPa
Water output l/h therm-RP 1200 | EH 1200 l/h therm-RP 1200 T | EH 1200 l/h therm-RP 1400 | EH 1400 l/h therm-RP 1400 T | EH 1400 l/h therm-RP 1600 | EH 1600 l/h therm-RP 1600 T | EH 1600 l/h
Admissible overpressure bar therm-RP 1200 | EH 210 bar therm-RP 1200 T | EH 210 bar therm-RP 1400 | EH 190 bar therm-RP 1400 T | EH 190 bar therm-RP 1600 | EH 170 bar therm-RP 1600 T | EH 170 bar
Admissible overpressure MPa therm-RP 1200 | EH 21 MPa therm-RP 1200 T | EH 21 MPa therm-RP 1400 | EH 19 MPa therm-RP 1400 T | EH 19 MPa therm-RP 1600 | EH 17 MPa therm-RP 1600 T | EH 17 MPa
Motor speed U/min therm-RP 1200 | EH 1400 U/min therm-RP 1200 T | EH 1400 U/min therm-RP 1400 | EH 1400 U/min therm-RP 1400 T | EH 1400 U/min therm-RP 1600 | EH 1400 U/min therm-RP 1600 T | EH 1400 U/min
Connection Voltage V therm-RP 1200 | EH 400 V therm-RP 1200 T | EH 400 V therm-RP 1400 | EH 400 V therm-RP 1400 T | EH 400 V therm-RP 1600 | EH 400 V therm-RP 1600 T | EH 400 V
Connection Phase ~ therm-RP 1200 | EH 3 ~ therm-RP 1200 T | EH 3 ~ therm-RP 1400 | EH 3 ~ therm-RP 1400 T | EH 3 ~ therm-RP 1600 | EH 3 ~ therm-RP 1600 T | EH 3 ~
Connection Frequency Hz therm-RP 1200 | EH 50 Hz therm-RP 1200 T | EH 50 Hz therm-RP 1400 | EH 50 Hz therm-RP 1400 T | EH 50 Hz therm-RP 1600 | EH 50 Hz therm-RP 1600 T | EH 50 Hz
Connection Amperage A therm-RP 1200 | EH 14,3 A therm-RP 1200 T | EH 14,3 A therm-RP 1400 | EH 14,3 A therm-RP 1400 T | EH 14,3 A therm-RP 1600 | EH 14,3 A therm-RP 1600 T | EH 14,3 A
Power intake kW therm-RP 1200 | EH 8 kW therm-RP 1200 T | EH 7,5 kW therm-RP 1400 | EH 8 kW therm-RP 1400 T | EH 8 kW therm-RP 1600 | EH 8 kW therm-RP 1600 T | EH 8 kW
Power output kW therm-RP 1200 | EH 6,3 kW therm-RP 1200 T | EH 5,5 kW therm-RP 1400 | EH 6,3 kW therm-RP 1400 T | EH 6,3 kW therm-RP 1600 | EH 6,3 kW therm-RP 1600 T | EH 6,3 kW
Power supply cable Length m therm-RP 1200 | EH 7.5 m therm-RP 1200 T | EH 7.5 m therm-RP 1400 | EH 7.5 m therm-RP 1400 T | EH 7.5 m therm-RP 1600 | EH 7.5 m therm-RP 1600 T | EH 7.5 m
Length mm therm-RP 1200 | EH 1050 mm therm-RP 1200 T | EH 1050 mm therm-RP 1400 | EH 1050 mm therm-RP 1400 T | EH 1050 mm therm-RP 1600 | EH 1050 mm therm-RP 1600 T | EH 1050 mm
Width mm therm-RP 1200 | EH 800 mm therm-RP 1200 T | EH 800 mm therm-RP 1400 | EH 800 mm therm-RP 1400 T | EH 800 mm therm-RP 1600 | EH 800 mm therm-RP 1600 T | EH 800 mm
Height mm therm-RP 1200 | EH 1050 mm therm-RP 1200 T | EH 1300 mm therm-RP 1400 | EH 1015 mm therm-RP 1400 T | EH 1300 mm therm-RP 1600 | EH 1015 mm therm-RP 1600 T | EH 1300 mm
Hot water output °C therm-RP 1200 | EH 12-80 °C therm-RP 1200 T | EH 12-80 °C therm-RP 1400 | EH 12-80 °C therm-RP 1400 T | EH 12-80 °C therm-RP 1600 | EH 12-80 °C therm-RP 1600 T | EH 12-80 °C
Steam level °C therm-RP 1200 | EH 140 °C therm-RP 1200 T | EH 140 °C therm-RP 1400 | EH 140 °C therm-RP 1400 T | EH 140 °C therm-RP 1600 | EH 140 °C therm-RP 1600 T | EH 140 °C
Oil consumption at max. heating output kg/h therm-RP 1200 | EH 7.7 kg/h therm-RP 1200 T | EH 7.7 kg/h therm-RP 1400 | EH 7.7 kg/h therm-RP 1400 T | EH 7.7 kg/h therm-RP 1600 | EH 7.7 kg/h therm-RP 1600 T | EH 7.7 kg/h
Oil consumption at max. heating output l/h therm-RP 1200 | EH 9.2 l/h therm-RP 1200 T | EH 9.2 l/h therm-RP 1400 | EH 9.2 l/h therm-RP 1400 T | EH 9.2 l/h therm-RP 1600 | EH 9.2 l/h therm-RP 1600 T | EH 9.2 l/h
Oil consumption T45 kg/h therm-RP 1200 | EH 5.6 kg/h therm-RP 1200 T | EH 5.6 kg/h therm-RP 1400 | EH 5.6 kg/h therm-RP 1400 T | EH 5.6 kg/h therm-RP 1600 | EH 5.6 kg/h therm-RP 1600 T | EH 5.6 kg/h
Oil consumption T45 l/h therm-RP 1200 | EH 6.6 l/h therm-RP 1200 T | EH 6.6 l/h therm-RP 1400 | EH 6.6 l/h therm-RP 1400 T | EH 6.6 l/h therm-RP 1600 | EH 6.6 l/h therm-RP 1600 T | EH 6.6 l/h
Heating output kW therm-RP 1200 | EH 84 kW therm-RP 1200 T | EH 84 kW therm-RP 1400 | EH 84 kW therm-RP 1400 T | EH 84 kW therm-RP 1600 | EH 84 kW therm-RP 1600 T | EH 84 kW
Weight kg therm-RP 1200 | EH 210 kg therm-RP 1200 T | EH 218 kg therm-RP 1400 | EH 210 kg therm-RP 1400 T | EH 218 kg therm-RP 1600 | EH 210 kg therm-RP 1600 T | EH 218 kg