Skip navigation

therm-RP 1600

Ord. no. 638800

The Kränzle therm-RP series is particularly suitable for applications where an above-average flushing effect at high working pressure is required. Thanks to the innovative in-line pump, these hot water units offer a water output of up to 1600 l/h as well as other convincing features.

  • Quick release plug-in system D12
  • Kränzle in-line RP pump
  • Total-stop system with delayed motor cut-of
  • Safety shutdown
  • Pressure regulation
  • Twist-Stop screw connection
  • Cleaning Agent Intake
  • Locking brake
  • Direct suction: Suction height 2.5 m
  • Water tank: Volume 12 liters
  • Digital thermostat
  • Flow monitor
  • Combustion chamber pre-ventilation
  • Visual flame monitoring
  • Overheating protection
  • Burner stops when there is a lack of heating oil
  • Operating hours meter
  • Fuel tank: 35 liters
  • Removable covers
  • Accessory storage
  • Digital control panel
  • Visual flame monitoring and Overheating protection
Operating pressure
70-150 bar
Water output
26.7 l/min
Connection Voltage
400 V
Connection Phase
3 ~
Connection Frequency
50 Hz
Hot water output
12-80 °C
Automotive industry, haulage companies
Agriculture, livestock farming
Public service, construction
Sanitary, food
Industry

Technical details

therm-RP 900 T
Ord. no. 638110
therm-RP 1200
Ord. no. 638402
therm-RP 1200 T
Ord. no. 638412
therm-RP 1400
Ord. no. 638600
therm-RP 1400 T
Ord. no. 638610
therm-RP 1600
Ord. no. 638800
therm-RP 1600 T
Ord. no. 638810
Ord. no. 638110638402638412638600638610638800638810
Operating pressure bar therm-RP 900 T 70-170 bar therm-RP 1200 70-190 bar therm-RP 1200 T 70-190 bar therm-RP 1400 70-170 bar therm-RP 1400 T 70-170 bar therm-RP 1600 70-150 bar therm-RP 1600 T 70-150 bar
Operating pressure MPa therm-RP 900 T 7-17 MPa therm-RP 1200 7-19 MPa therm-RP 1200 T 7-19 MPa therm-RP 1400 7-17 MPa therm-RP 1400 T 7-17 MPa therm-RP 1600 7-15 MPa therm-RP 1600 T 7-15 MPa
Water output l/h therm-RP 900 T 900 l/h therm-RP 1200 1200 l/h therm-RP 1200 T 1200 l/h therm-RP 1400 1400 l/h therm-RP 1400 T 1400 l/h therm-RP 1600 1600 l/h therm-RP 1600 T 1600 l/h
Admissible overpressure bar therm-RP 900 T 190 bar therm-RP 1200 210 bar therm-RP 1200 T 210 bar therm-RP 1400 190 bar therm-RP 1400 T 190 bar therm-RP 1600 170 bar therm-RP 1600 T 170 bar
Admissible overpressure MPa therm-RP 900 T 19 MPa therm-RP 1200 21 MPa therm-RP 1200 T 21 MPa therm-RP 1400 19 MPa therm-RP 1400 T 19 MPa therm-RP 1600 17 MPa therm-RP 1600 T 17 MPa
Motor speed U/min therm-RP 900 T 1400 U/min therm-RP 1200 1400 U/min therm-RP 1200 T 1400 U/min therm-RP 1400 1400 U/min therm-RP 1400 T 1400 U/min therm-RP 1600 1400 U/min therm-RP 1600 T 1400 U/min
Connection Voltage V therm-RP 900 T 400 V therm-RP 1200 400 V therm-RP 1200 T 400 V therm-RP 1400 400 V therm-RP 1400 T 400 V therm-RP 1600 400 V therm-RP 1600 T 400 V
Connection Phase ~ therm-RP 900 T 3 ~ therm-RP 1200 3 ~ therm-RP 1200 T 3 ~ therm-RP 1400 3 ~ therm-RP 1400 T 3 ~ therm-RP 1600 3 ~ therm-RP 1600 T 3 ~
Connection Frequency Hz therm-RP 900 T 50 Hz therm-RP 1200 50 Hz therm-RP 1200 T 50 Hz therm-RP 1400 50 Hz therm-RP 1400 T 50 Hz therm-RP 1600 50 Hz therm-RP 1600 T 50 Hz
Connection Amperage A therm-RP 900 T 9,4 A therm-RP 1200 14,3 A therm-RP 1200 T 14,3 A therm-RP 1400 14,3 A therm-RP 1400 T 14,3 A therm-RP 1600 14,3 A therm-RP 1600 T 14,3 A
Power intake kW therm-RP 900 T 5,5 kW therm-RP 1200 8 kW therm-RP 1200 T 8 kW therm-RP 1400 8 kW therm-RP 1400 T 8 kW therm-RP 1600 8 kW therm-RP 1600 T 8 kW
Power output kW therm-RP 900 T 4,0 kW therm-RP 1200 6,3 kW therm-RP 1200 T 6,3 kW therm-RP 1400 6,3 kW therm-RP 1400 T 6,3 kW therm-RP 1600 6,3 kW therm-RP 1600 T 6,3 kW
Power supply cable Length m therm-RP 900 T 7.5 m therm-RP 1200 7.5 m therm-RP 1200 T 7.5 m therm-RP 1400 7.5 m therm-RP 1400 T 7.5 m therm-RP 1600 7.5 m therm-RP 1600 T 7.5 m
Length mm therm-RP 900 T 1050 mm therm-RP 1200 1050 mm therm-RP 1200 T 1050 mm therm-RP 1400 1050 mm therm-RP 1400 T 1050 mm therm-RP 1600 1050 mm therm-RP 1600 T 1050 mm
Width mm therm-RP 900 T 800 mm therm-RP 1200 800 mm therm-RP 1200 T 800 mm therm-RP 1400 800 mm therm-RP 1400 T 800 mm therm-RP 1600 800 mm therm-RP 1600 T 800 mm
Height mm therm-RP 900 T 1300 mm therm-RP 1200 1015 mm therm-RP 1200 T 1300 mm therm-RP 1400 1015 mm therm-RP 1400 T 1300 mm therm-RP 1600 1015 mm therm-RP 1600 T 1300 mm
Hot water output °C therm-RP 900 T 12-85 °C therm-RP 1200 12-80 °C therm-RP 1200 T 12-80 °C therm-RP 1400 12-80 °C therm-RP 1400 T 12-80 °C therm-RP 1600 12-80 °C therm-RP 1600 T 12-80 °C
Steam level °C therm-RP 900 T 155 °C therm-RP 1200 140 °C therm-RP 1200 T 140 °C therm-RP 1400 140 °C therm-RP 1400 T 140 °C therm-RP 1600 140 °C therm-RP 1600 T 140 °C
Oil consumption at max. heating output kg/h therm-RP 900 T 5.8 kg/h therm-RP 1200 7.7 kg/h therm-RP 1200 T 7.7 kg/h therm-RP 1400 7.7 kg/h therm-RP 1400 T 7.7 kg/h therm-RP 1600 7.7 kg/h therm-RP 1600 T 7.7 kg/h
Oil consumption at max. heating output l/h therm-RP 900 T 6.8 l/h therm-RP 1200 9,2 l/h therm-RP 1200 T 9,2 l/h therm-RP 1400 9.2 l/h therm-RP 1400 T 9.2 l/h therm-RP 1600 9.2 l/h therm-RP 1600 T 9.2 l/h
Oil consumption T45 kg/h therm-RP 900 T 4.2 kg/h therm-RP 1200 5.6 kg/h therm-RP 1200 T 5.6 kg/h therm-RP 1400 5.6 kg/h therm-RP 1400 T 5.6 kg/h therm-RP 1600 5.6 kg/h therm-RP 1600 T 5.6 kg/h
Oil consumption T45 l/h therm-RP 900 T 5.0 l/h therm-RP 1200 6.6 l/h therm-RP 1200 T 6.6 l/h therm-RP 1400 6.6 l/h therm-RP 1400 T 6.6 l/h therm-RP 1600 6.6 l/h therm-RP 1600 T 6.6 l/h
Heating output kW therm-RP 900 T 60 kW therm-RP 1200 84 kW therm-RP 1200 T 84 kW therm-RP 1400 84 kW therm-RP 1400 T 84 kW therm-RP 1600 84 kW therm-RP 1600 T 84 kW
Weight kg therm-RP 900 T 205 kg therm-RP 1200 210 kg therm-RP 1200 T 218 kg therm-RP 1400 210 kg therm-RP 1400 T 218 kg therm-RP 1600 210 kg therm-RP 1600 T 218 kg